null
Ireland EU online store
Victron Energy

Victron Energy Cyrix-i Intelligent Combiner - 24V/48V (400A)

SKU:
VCYR020400000
UPC:
8719076022305
€338.95
Frequently bought together:

Description

Intelligent battery monitoring to prevent unwanted switching

Some battery combiners will disconnect a battery in case of a short but high amperage load. A battery combiner also may fail to connect a large but discharged battery bank because the DC voltage immediately drops below the disengage value once the batteries are connected. The software of the Cyrix-i does more than simply connect and disconnect based on battery voltage and with a fixed time delay. The Cyrix-i looks at the general trend (voltage increasing or decreasing) and reverses a previous action only if the trend has reversed during a certain period of time. The time delay depends on the voltage deviation from the trend.

No voltage loss

Cyrix battery combiners are an excellent replacement for diode isolators. The main feature is that there is virtually no voltage loss so that the output voltage of alternators or battery chargers does not need to be increased.

Prioritising the starter battery

In a typical setup the alternator is directly connected to the starter battery. The accessory battery, and possibly also a bow thruster and other batteries are each connected to the starter battery with Cyrix battery combiners. When a Cyrix senses that the starter battery has reached the connect voltage it will engage, to allow for parallel charging of the other batteries.

Bidirectional voltage sensing and power supply from both batteries

The Cyrix senses the voltage of both connected batteries. It will therefore also engage if for example the accessory battery is being charged by a battery charger. The Cyrix-ct 12/24 has a dual power supply. It will therefore also close if the voltage on one battery is too low to operate the Cyrix. In order to prevent unexpected operation during installation or when one battery has been disconnected, the Cyrix-ct 12/24 will not close if the voltage on one of the two battery connections is lower than 2 V (12 V battery) or 4 V (24 V battery).

Parallel connection in case of emergency (Start Assist)

The Cyrix can also be engaged with a push button (Cyrix remains engaged during 30 seconds) or a switch to connect batteries in parallel manually. This is especially useful in case of emergency when the starter battery is discharged or damaged.

Specifications

  • Continuous current: 400 A
  • Peak current: 2000 A during 1 second
  • Input voltage 24 V/48 V: 16 V - 72 V
  • Over voltage disconnect: 16 V/32 V/64 V
  • Current consumption when open: 4 mA
  • Emergency start: Yes, 30 s
  • Micro switch for remote monitoring: Yes
  • Status indication: Bicolour LED
  • Height: 78 mm (3.1")
  • Width: 102 mm (4")
  • Depth: 110 mm (4.4")
  • Weight: 0.9 kg (2 lbs)

Technical Files

Datasheet
Declaration of Conformity

View AllClose