null
Ireland EU online store
Sika

Sikaflex 291i Sealant 300ml

€17.95
Frequently bought together:

Description

Sikaflex®-291i is a multipurpose product used in marine constructions. It is suitable for making elastic, vibration-resistant joint seals, and can also be used for a variety of interior sealing applications. Sikaflex®-291i bonds extremely well to the materials commonly used in marine construction like wood, metals, metal primers and paint coatings (2-C systems), ceramic materials and plastics (GRP, etc.). Sikaflex®-291i must not be used to seal plastics that are prone to stress cracking (e.g. PMMA, PC, etc.). 

Features

  • Wheelmark approved
  • 1-component formulation
  • Highly elastic
  • Low odour
  • Non-corrosive
  • Can be painted
  • Bonds well to a wide variety of marine substrates
  • Solvent free
  • Very low VOC
  • Low isocyanate content

Sealing applications

  • Chain plates
  • Deck Fittings & Hardware
  • Hatches
  • Ports, etc.

 Specifications

  • Chemical base: 1-component polyurethane
  • Colours: White, Black
  • Cure mechanism: Moisture-curing
  • Density: 1.3 kg/L
  • Non-sag properties: Good
  • Application temperature: 10-40 degrees C (ambient)
  • Skin time (CQP019-1): 60 minutes
  • Open time (CQP526-1): 45 minutes
  • Shrinkage (CQP014-1): 2%
  • Shore A hardness (CQP023-1/ ISO7619-1): 40
  • Tensile strength: (CQP036-1/ ISO 527): 1.8 MPa
  • Elongation at break (CQP036-1/ ISO 527):  700%
  • Tear propagation resistance (CQP045-1/ ISO 34): 7N/mm
  • Service temperature (CQP513-1): -50 to 90 degrees C, 4 hours 120 degrees C, 1 hour 140 degrees C
  • Shelf life (CQP016-1): 12 months

Application

Surface preparation

Surfaces must be clean, dry and free from grease, oil and dust.

Surface treatment depends on the specific nature of the substrates and is crucial for a long lasting bond. Suggestions for surface preparation may be found on the current edition of the appropriate Sika® Pre-Treatment Chart. Consider that these suggestions are based on experience and have in any case to be verified by tests on original substrates.

Application

Sikaflex®-291i can be processed between 10 °C and 40 °C but changes in reactivity and application properties have to be considered. The optimum temperature for substrate and sealant is between 15 °C and 25 °C.

Sikaflex®-291i can be processed with hand, pneumatic or electric driven piston guns.

Tooling and finishing

Tooling and finishing must be carried out within the skin time of the sealant. It is recommended using Sika® Tooling Agent N. Other finishing agents must be tested for suitability and compatibility prior the use.

Removal

Uncured Sikaflex®-291i can be removed from tools and equipment with Sika® Remover-208 or another suitable solvent. Once cured, the material can only be removed mechanically. Hands and exposed skin have to be washed immediately using Sika® Cleaner-350H cleaning towels or a suitable industrial hand cleaner and water. Do not use solvents on skin!

Overpainting

Sikaflex®-291i can be best painted after formation of a skin. Painting could be improved by treating the joint surface with Sika® Aktivator-100 or Sika® Aktivator-205 prior to paint process. If the paint requires a baking process (> 80 °C), best performance is achieved by allowing the sealant to fully cure first. All paints have to be tested by carrying preliminary trials under manufacturing conditions. The elasticity of paints is usually lower than that of sealants. This could lead to cracking of the paint in the joint area.


Product safety

Please note the following hazard warnings:
Hazard pictogram(s):
Signal word: Danger
Hazard statement(s):

H317 May cause an allergic skin reaction.
H334 May cause allergy or asthma symptoms or breathing difficulties if inhaled. .
H350i May cause cancer by inhalation.
H373 May cause damage to organs (hearing organs) through prolonged or repeated exposure if inhaled.

Precautionary statement(s): Prevention:
P201 Obtain special instructions before use.
P202 Do not handle until all safety precautions have been read and understood.
P260 Do not breathe dust/ fume/ gas/ mist/ vapors/ spray.
P272 Contaminated work clothing must not be allowed out of the workplace.
P280 Wear protective gloves.
P281 Use personal protective equipment as required.
P285 In case of inadequate ventilation wear respiratory protection.
Response:
P302 + P352 IF ON SKIN: Wash with plenty of soap and water.
P304 + P341 IF INHALED: If breathing is difficult, remove person to fresh air and keep comfortable for breathing.
P308 + P313 IF exposed or concerned: Get medical advice/ attention.
P333 + P313 If skin irritation or rash occurs: Get medical advice/ attention.
P363 Wash contaminated clothing before reuse.
Storage:
P405 Store locked up.
Disposal:
P501 Dispose of contents/ container to an approved waste disposal plant.
Warning: Reports have associated repeated and prolonged exposure to some of the chemicals in this product with permanent brain,liver, kidney and nervous system damage. Intentional misuse by deliberate concentration and inhalation of vapors may be harmful or fatal.

Ireland  Safety Data Sheet pdf

Ireland  Safety Data Sheet pdf

View AllClose